Bathroom electrical zones explained

By Azzeddine Kebbi, NAPIT-registered electrician and director of Kebbi Electrical Services · Updated 10 November 2026

Bathroom zones are areas around a bath or shower that set what electrical equipment is allowed there. Zone 0 is inside the bath or shower tray, zone 1 is the space directly above it, and zone 2 is the strip 0.6 m wide beside it. The closer to water, the stricter the rules.

NAPIT registeredWinner Quality Business Awards 2025 & 2026Tested & certified

The zones

Zone 0

Inside the bath or shower tray itself. Only very low voltage equipment rated at least IPX7.

Zone 1

Directly above the bath or shower tray, up to 2.25 m from the floor. Equipment must be at least IPX4.

Zone 2

0.6 m beyond zone 1, up to 2.25 m high. Equipment must be at least IPX4.

Outside the zones

The rest of the room. Normal fittings are allowed if they suit a damp room.

The main rules

  • Every circuit serving a bathroom needs 30 mA RCD protection.
  • Standard sockets are only allowed at least 3 m from the edge of zone 1, which rules them out in most bathrooms.
  • Shaver supply units made for bathrooms can go in zone 2.
  • Light switches are usually pull cords, or placed outside the room.
  • Fittings in zones 1 and 2 need the right IP rating for splashes, and higher if water jets are used for cleaning.

Is bathroom electrical work notifiable?

In England, adding or altering a circuit within the zones around a bath or shower is notifiable under Part P. A registered electrician certifies the work and notifies building control for you. See what is a Part P certificate.

Common questions

Can I have a plug socket in a bathroom?

Only if it is at least 3 m from the edge of zone 1, which most bathrooms are too small for. Shaver sockets made for bathrooms are the exception.

What IP rating do bathroom lights need?

At least IPX4 in zones 1 and 2. Many people choose IP65 downlights for showers for extra protection.

What is IPX4?

It means the fitting is protected against water splashing from any direction.

Does a bathroom extractor fan need an isolator?

A fan isolator switch lets the fan be switched off safely for maintenance. It is normally fitted outside the zones or outside the room. See what is an isolator switch.